| 1.Failed
to adjust the power of jet |
|
| Reason: |
The small electromotor in the air control box
cannot move and that leads to the failure of the
valve's flexing. Or maybe the pipe leaks air. |
| Check: |
1.If pipe leakage, or tie-in loose
2.If connection pole loose
3.If the plastic valve locked
4.If air switch button is broken
5.If the connection between the air switch &
the pipe loose
6.If the air switch out of order
7.If the line connection is loose
8.If the air pipe is blocked
9.If the electromotor is burnout |
| Check: |
1.If the connection tight
2.If the cool & hot water faucet is loose
3.If the valve out of order |
| 3.Steam
box water leakage |
|
| Reason: |
usually leakage is aroused from wrong installation.
If the installation was done carefully, that will
be avoided. Please use glass cement when found the
leakage. |
| |
1.leakage when power off:
A: Pipe broken
B: Pipe connection is too loose or to tight
C: Resident water & pipe system problems
2.leakage when using steam.
A:
B: Water tank is damaged
C: The joint 0f steam generator and water tank is
broken
D: The venthole of the steam generator is not sealed
well.
3.leakage when using the jets
A: The steam box is not sealed with or the glass
cement loose.
B: The glass door is not sealed well.
C: The air control switch of the steam box with
bathtub is not sealed well.
D: The electric valve for the jets is out of order
4.leakage when water runs out
A: Check the drainage
B: Drainage pipe is broken
C: Drainage moves away from the sewer.
D: The sewer is blocked. |
| 4.Nozzle
fails to jet or jet softly |
|
| |
A.Fail to jet: check the electric valve if
in power
1. If no power, then the circuit is out of order;
if the electric board fails to display, then it
is out of order; if the electric board works well
then just check the audion , if it is burnout.
2. If in power, check the electric valve if in order.
3. If the electric valve works well , then check
if water can runs smooth or blocked.
4. Check if the water shift turns to the jet position
or not
B.Jet softly.
1. The resident water pressure is too low
2. Adjust the jet gasket to make the water jet from
the three holes.
3. The joint or the jet hole blocked.
4. The water valve is not opened completely |
| 5.The exhaust
fan cannot turn. |
|
| |
A.Failure after installation
1. Check if you upend the anode & cathode
2. If the link connected wrongly
B.Failure after use
1. If the electric bnc connector plugs loose
2. If contact well
3. If the line jointing loose
4. If no electricity, then the electric board or
the circuit is out of order. |
| 6.Radio
without sound or can not reach any channel |
|
| |
1. If there is no any radio & circuit
sound, For F1 series failure always aroused on the
electric board. While For F2 series failure from
the circuit.
2. F2. if hearing the channel signal sound
after turning on the radio, then check if the speaker
works well or not.
3. If there is no channel signal sound, Then
the small relay which controls the radio must be
out of order. |
| 7.The fuse
burns out or the house electric valve trips when
using steam. |
|
| |
If that happens after using a period of time,
it shows that the capability of the creepage switch
& the fuse is too limited.It will be normal
to change a better one. |
|
|
 |
|
 |
| Copyright 2003 GUANGZHOU BIAOPAI